Prepared For:
Sample Buyer
Property Address:
39 Chickory Lake
Whoville, NC
![]() |
| Date: 11/26/2004 | Time: 1:30 PM | Report ID: sample 2 |
| Property: 39 Chickory Lake Whoville, NC |
Customer: Sample Buyer |
Real Estate Professional: |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
| Age Of Home: Over 50 Years | Client Is Present: Yes | Radon Test: not performed |
| Water Test: No | Weather: Cloudy | Temperature: Below 60 |
| Rain in last 3 days: Yes |
![]() |
| Styles & Materials FOUNDATION: MASONRY BLOCK POURED CONCRETE FLOOR STRUCTURE: 2 X 8 2 X 10 WOOD JOISTS WALL STRUCTURE: WOOD MASONRY COLUMNS OR PIERS: MASONRY BLOCK SUPPORTING WALLS CEILING STRUCTURE: 2X6 ROOF STRUCTURE: STICK-BUILT 2 X 8 RAFTERS COMMON BOARD ROOF-TYPE: GABLE |
||||||||||||||||||||||||||||||||||||||||||||||||
![]() 1.5 Picture 1 |
| Styles & Materials SIDING STYLE: CEMENT STUCCO SIDING MATERIAL: STONE MASONRY EXTERIOR ENTRY DOORS: WOOD WINDOW TYPES: SINGLE PANE CASEMENT APPURTENANCE: BALCONY PATIO AUTO OPENER MANUFACTURER: N/A GARAGE DOOR MATERIAL: WOOD GARAGE DOOR TYPE: TWO MANUAL DRIVEWAY: ASPHALT |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() 2.1 Picture 1 |
![]() 2.1 Picture 2 |
![]() 2.4 Picture 1 | ![]() 2.4 Picture 2 |
![]() 2.4 Picture 3 |
![]() 2.5 Picture 1 |
![]() 2.5 Picture 2 | ![]() 2.5 Picture 3 |
![]() 2.5 Picture 4 |
![]() 2.6 Picture 1 | ![]() 2.6 Picture 2 |
| Styles & Materials ROOF COVERING: TILE RUBBER MEMBRANE VIEWED ROOF COVERING FROM: GROUND CHIMNEY (exterior): MASONRY/STUCCO |
||||||||||||||||||||||||||||||||||||
![]() 3.0 Picture 1 |
![]() 3.0 Picture 2 |
![]() 3.0 Picture 3 |
![]() 3.1 Picture 1 |
![]() 3.1 Picture 2 |
![]() 3.3 Picture 1 |
| Styles & Materials WATER SOURCE: PUBLIC PLUMBING SUPPLY: NOT VISIBLE PLUMBING DISTRIBUTION: GALVANIZED COPPER POLY WASHER DRAIN SIZE: NOT VISIBLE PLUMBING WASTE: PVC CAST IRON (OLD) WATER HEATER POWER SOURCE: GAS (QUICK RECOVERY) CAPACITY: 50 GAL (2-3 PEOPLE) MANUFACTURER: PENNFIELD |
||||||||||||||||||||||||||||||||||||||||||||||||
![]() 4.1 Picture 1 | ![]() 4.1 Picture 2 |
![]() 4.1 Picture 3 |
![]() 4.3 Picture 1 |
![]() 4.4 Picture 1 |
| Styles & Materials ELECTRICAL SERVICE CONDUCTORS: BELOW GROUND ALUMINUM 220 VOLTS PANEL CAPACITY: 200 AMP PANEL TYPE: CIRCUIT BREAKERS BRANCH WIRE 15 and 20 AMP: COPPER WIRING METHODS: ROMEX CONDUIT NOT VISIBLE |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() 5.3 Picture 1 | ![]() 5.3 Picture 2 |
![]() 5.3 Picture 3 |
![]() 5.3 Picture 4 |
No outlet in Hall Bath except for one that is built in light fixture. These outlets are considered unsafe if not grounded and bathroom should have its own duplex GFCI outlet (Ground Fault Circuit Interrupter).
| Styles & Materials HEAT TYPE: CIRCULATING BOILER ENERGY SOURCE: OIL NUMBER OF HEAT SYSTEMS (excluding wood): ONE TYPES OF FIREPLACES: NON-VENTED GAS LOGS OPERABLE FIREPLACES: ONE NUMBER OF WOODSTOVES: NONE |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Liner for fireplace or boiler were not inspected by our company. Recommend a qualified chimney sweep inspect for safety.
![]() 6.3 Picture 1 |
| Styles & Materials COOLING EQUIPMENT TYPE: AIR CONDITIONER UNIT COOLING EQUIPMENT ENERGY SOURCE: ELECTRICITY NUMBER OF A/C UNITS: ONE |
||||||||||||||||||||||||||||||||||||
![]() 7.2 Picture 1 |
![]() | ![]() |
![]() | ![]() |
![]() | ![]() |
![]() |
| Styles & Materials CEILING MATERIALS: PLASTER WALL MATERIAL: PLASTER FLOOR COVERING(S): CARPET TILE WOOD CABINETRY: WOOD VENEER COUNTERTOP: GRANITE |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() 8.0 Picture 1 |
![]() 8.0 Picture 2 |
![]() 8.1 Picture 1 |
![]() 8.1 Picture 2 |
![]() 8.6 Picture 1 |
| Styles & Materials ATTIC INSULATION: BLOWN FIBERGLASS R- VALUE: R-30 OR BETTER VENTILATION: PASSIVE EXHAUST FAN TYPES: NONE DRYER POWER SOURCE: 22O ELECTRIC DRYER VENT: FLEXIBLE METAL PVC RIGID |
||||||||||||||||||||||||||||||||||||
![]() 9.2 Picture 1 |
| Styles & Materials DISHWASHER: MAYTAG DISPOSER: KITCHEN AIDE RANGE/OVEN: GENERAL ELECTRIC BUILT-IN MICROWAVE: GENERAL ELECTRIC TRASH COMPACTORS: GENERAL ELECTRIC |
||||||||||||||||||||||||||||||||||||||||||||||||
![]() 10.5 Picture 1 |
![]() HomeBuyers Inspection HBI
18 Business Park Circle |
Customer |
Property Address |
| 1.0 | FOUNDATIONS (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) | |
| Inspected | ||
|
Crawlspace is limited in access due to plumbing pipes and was not inspected by my company. |
||
| 2.0 | WALL CLADDING FLASHING AND TRIM | |
| Repair or Replace | ||
|
Stucco over-all appears good except for some areas peeling where obvious. For example on rear of home around balcony porch at rear and at chimney. |
||
| 2.1 | DOORS (Exterior) | |
| Repair or Replace | ||
|
Entry door at rear of home deteriorated at bottom of jamb(s). A repair or replacement is needed. Recommend repair or replace as needed using a qualified person. |
||
|
Entry door to rear balcony is deteriorated at bottom. A repair or replacement is needed. Recommend repair or replace as needed using a qualified person. |
||
| 2.3 | GARAGE DOOR OPERATORS (Report whether or not doors will reverse when met with resistance) | |
| Not Present | ||
|
The Two door Garage at rear of home appears narrow and may not allow large cars to enter. |
||
| 2.4 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS | |
| Repair or Replace | ||
|
The balcony in rear has loose or missing stucco and water intrusion is occurring through concrete wall. Repairs are needed. Recommend a qualified mason perform the work. |
||
| 2.5 | VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIOS, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building) | |
| Repair or Replace | ||
|
Ground Drain located at rear of home at basement/garage entry will need periodical cleaning and maintenance. I am unable to determine if water will over-run or by-pass drain even if kept clean under certain weather conditions. |
||
| 2.6 | EAVES, SOFFITS AND FASCIAS | |
| Repair or Replace | ||
|
Wood fascia at eave on rear of home are weathered and deteriorated. Repairs can involve removal of guttering to replace fascia board. Photo shows blackened fascia with white mold on kitchen side of rear. Paint is peeling on front of home at wood trim or fascia that may include deterioration. Recommend a qualified contractor inspect and repair as needed. |
||
| 3.0 | ROOF COVERINGS | |
| Not Inspected | ||
|
Due to the fact that this home has a tile roof, I am not qualified to inspect this roof in a way that is considered thorough. Tile roofs can leak and not show an obvious cause during a routine inspection. A separate inspection by a qualified roofing contractor who specializes in tile roof replacement should inspect this roof before you purchase. Tile roofs can be expensive to repair or replace. |
||
|
EPDM rubber membrane roof on balcony above kitchen appears unfinished with plastic draped in areas and according to the sellers comments. I strongly recommend a warranty request from the roofing contractor performing this work. The damage to the kitchen ceiling from this leak is noted in the Interiors section. I did not inspect cavity between joists for possible existence of mold that can be caused by a leak. |
||
|
Roof tile is cracked above front porch. Other cracks, imperfections in installation or performance may exist on roof of home. |
||
| 3.1 | FLASHINGS | |
| Repair or Replace | ||
|
Leak sign in attic near chimney of Living room. See roof covering notes. |
||
|
Flashing edge is laid flat on side wall or did not tuck into wall and is exposed or may allow water to enter at rear of home on lower roof. Other areas may exist and was not inspected by my company. See roofing notes. |
||
| 4.1 | INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES | |
| Inspected | ||
|
Polybutylene plastic plumbing supply lines (PB) are installed in the subject house. Polybutylene has been used in this area for many years, but has had a higher than normal failure rate, and is no longer being widely used. Copper and Brass fittings used in later years have apparently reduced the failure rate. This subject house has copper fittings. For further details contact the Consumer Plumbing Recovery center at 1-800-392-7591 or the web at http://www.pbpipe.com |
||
| 5.3 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) | |
| Repair or Replace | ||
|
"Three-prong" outlet is not grounded. Needs correcting in Bedroom at end of hall in back room. Also outlet cover is damaged at middle bedroom. Electrical issues are considered a hazard until repaired. Recommend repair as needed. |
||
|
Outlet in middle bedroom is old and the shape of recepticle is out dated and can no longer be used with standard plugs. |
||
|
Doorbell is missing. |
||
| 5.5 | OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS) | |
| Repair or Replace | ||
|
No outlet found in hall bath. Recommend a duplex GFCI outlet be installed by a licensed electrician. No outlet in Hall Bath except for one that is built in light fixture. These outlets are considered unsafe if not grounded and bathroom should have its own duplex GFCI outlet (Ground Fault Circuit Interrupter). |
||
| 6.3 | CHIMNEYS, FLUES AND VENTS | |
| Not Inspected | ||
|
Vent pipe for oil fired boiler needs mastic sealed around pipe where it enters chimney. This is a safety issue and should be repaired. Recommend a qualified licensed heat contractor inspect further and repair as needed. Liner for fireplace or boiler were not inspected by our company. Recommend a qualified chimney sweep inspect for safety. |
||
| 7.2 | DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) | |
| Repair or Replace | ||
|
Disposable filters is dirty. Clogged filters can raise energy bill and shorten life span of compressor. Recommend repair or replace as needed using a qualified person. |
||
| 7.3 | PRESENCE OF INSTALLED COOLING SOURCE IN EACH ROOM | |
| Inspected | ||
|
Cooling equipment serves the upstairs of home only. The main level has no cooling source (FYI). |
||
| 8.1 | WALLS | |
| Repair or Replace | ||
|
Bubble in paint or plaster coating indicates moisture has affected it either by wall or window. Recommend search for a possible cause and repair as needed to prevent possible further damage over extended period. |
||
|
Water intrusion signs in basement/garage and wood deterioration at bathroom stall is present. Water intrusion may be from ground drain in front of door becoming clogged or drain may not be adequate in certain weather conditions. Repair as desired. |
||
| 8.6 | WINDOWS (REPRESENTATIVE NUMBER) | |
| Inspected | ||
|
Some glass is cracked in windows of home. Cracked glass can cause air infiltration or may cause an injury. Recommend repair as needed using a qualified contractor. |
||
| 9.0 | INSULATION AND VAPOR RETARDERS (in unfinished spaces) | |
| Inspected | ||
|
Floor system is not insulated. Heat loss can occur more on this home than one that is properly insulated. |
||
| 9.2 | VENTING SYSTEMS (Kitchens, baths and laundry) | |
| Inspected | ||
|
Dryer vent piping turns up before exiting home and may require periodical cleaning. |
||
| 10.5 | MICROWAVE COOKING EQUIPMENT | |
| Inspected | ||
|
Recommend checking with manufacturer of microwave for clearance requirements between range top and microwave as a precaution. This unit appears lower than normal. |
||
Prepared Using HomeGauge http://www.homegauge.com SHGI (c) 2000-2004 : Licensed To :Napoleon Home Inspections
|
INVOICE |
| HomeBuyers Inspection HBI
18 Business Park Circle Arden, NC 28704 877-274-4299 Inspected By: Russell Buchanan#306 |
Inspection Date: 11/26/2004
Report ID: sample 2 |
| Customer Info: | Inspection Property: |
| Sample Buyer
Customer's Real Estate Professional: |
39 Chickory Lake Whoville, NC |
Inspection Fee:
| ||||
Tax $0.00 | ||||
| Total Price $0.00 |
Payment Method:
Payment Status:
Note:
![]() HomeBuyers Inspection HBI
18 Business Park Circle |
This inspection was performed in accordance with and under the terms of a Pre-Inspection Agreement. The agreement was signed and agreed upon before the preparation of this report and a signed copy of the agreement is available upon request. An unsigned copy of the agreement may be attached to this report for your information or it may also be available on the home inspection company web site.
1.0 Picture 1